Engine oil cooler clogging / failure

Reliability tier: verified - verify before ordering, see /disclosure/

Symptoms

Root cause

The engine oil cooler sits in the valley and coolant flows through it before reaching the EGR cooler. Its coolant passages are narrow and clog with the silicate sludge / casting debris described in fm-6-0-coolant-system-neglect. A restricted oil cooler both overheats the oil and starves the EGR cooler, which is why the EGR cooler keeps failing until the oil cooler is addressed.

Diagnosis

Fixes

replace the oil cooler; thoroughly flush the cooling system at the same time ()

install coolant filtration to prevent recurrence ()

for high-power or heavy-tow builds, an external / relocated oil cooler kit ()

Prevalence

near-universal

Affected configurations (37)